{"id":10789,"date":"2026-06-19T13:49:08","date_gmt":"2026-06-19T13:49:08","guid":{"rendered":"https:\/\/etaanalitik.com\/urun\/lam-504-liquid-activity-monitor\/"},"modified":"2026-09-03T11:45:27","modified_gmt":"2026-09-03T11:45:27","slug":"lam-504-liquid-activity-monitor","status":"publish","type":"product","link":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/","title":{"rendered":"LAM-504 Liquid Activity Monitor"},"content":{"rendered":"<p><strong>The LAM-504 Liquid Activity Monitor<\/strong> is a fixed radiation monitoring system developed for the measurement of volumetric activity of gamma-emitting radionuclides within process liquids, steam, or steam-air mixtures in nuclear facilities.<\/p>\n<p>The LAM-504 assists in the continuous monitoring of radioactivity levels in process circuits under routine operating conditions. The system operates with an ATL-type detector structure directly mounted on the measured pipeline, enabling measurements from an appropriate distance to the process line. <\/p>\n<p>The GD-52 gamma detector is utilized with a NaI(Tl) scintillator crystal, lead collimator, and LED control\/stabilization source. For high-temperature pipelines, YAP(Ce) crystal or cooled model options may be selected depending on the application. <\/p>\n<p>The RPU-06 radiation processing unit and DIM-15 digital multichannel analyzer facilitate the processing, local display, archiving of measurement results, and monitoring of alarm levels. In the default configuration, the total volumetric gamma activity is determined according to the selected reference radionuclide. <\/p>\n<p>The optional spectrometric function enables the identification and quantitative assessment of up to 16 gamma-emitting radionuclides. The RadSpec software is employed for configuring the device&#8217;s spectrometric parameters and for calibration procedures. <\/p>\n<h3><strong>Key Features<\/strong><\/h3>\n<ul>\n<li>Gamma activity measurement in process liquids, steam, and steam-air mixtures<\/li>\n<li>ATL-type monitor structure directly mounted on the pipeline<\/li>\n<li>GD-52 NaI(Tl) gamma detector<\/li>\n<li>Automatic spectrum stabilization with LED control source<\/li>\n<li>Optional analysis of up to 16 radionuclides<\/li>\n<li>Local display and alarm monitoring with RPU-06 processing unit<\/li>\n<li>Configuration and calibration with RadSpec software<\/li>\n<li>RS-485 Modbus RTU and Ethernet Modbus TCP interfaces<\/li>\n<\/ul>\n<h3><strong>Application Areas<\/strong><\/h3>\n<ul>\n<li>Radiation Monitoring Systems<\/li>\n<li>Liquid Effluent Monitoring<\/li>\n<li>Process Radiation Monitoring<\/li>\n<li>Radioactive Emission Monitoring<\/li>\n<li>Nuclear Power Plants<\/li>\n<li>Nuclear Facilities and Research Reactors<\/li>\n<li>Radioactive Waste Management<\/li>\n<li>Environmental Radiation Measurements<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.<\/p>\n<p><button> <i class=\"fa fa-download\"> <\/i> <span style=\"color: #ffffff;\"><a style=\"color: #ffffff;\" href=\"https:\/\/etaanalitik.com\/wp-content\/uploads\/2026\/06\/VF2602250143_LAM-504_datasheet.pdf\" target=\"_blank\" rel=\"noopener\">Product Brochure<\/a><\/span><\/button><\/p>\n","protected":false},"featured_media":10791,"menu_order":0,"template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false},"product_brand":[753],"product_cat":[525,513,515],"product_tag":[569,628,528,526,589,533,540,518],"class_list":["post-10789","product","type-product","status-publish","has-post-thumbnail","product_brand-bertin-nuclear","product_cat-environmental-and-outdoor-radiation","product_cat-radiation-monitoring-systems","product_cat-radioactive-waste-management-characterization","product_tag-environmental-radiation-measurements","product_tag-liquid-effluent-monitoring","product_tag-nuclear-facilities-and-research-reactors","product_tag-nuclear-power-plants","product_tag-process-radiation-monitoring","product_tag-radiation-monitoring-systems","product_tag-radioactive-emission-monitoring","product_tag-radioactive-waste-management","first","instock","shipping-taxable","product-type-simple"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.0.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.0.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ETA Analitik Sistemler - Hassas \u00d6l\u00e7\u00fcm, G\u00fcvenilir \u00c7\u00f6z\u00fcm\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler\" \/>\n\t\t<meta property=\"og:description\" content=\"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-06-19T13:49:08+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-03T11:45:27+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler\" \/>\n\t\t<meta name=\"twitter:description\" content=\"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/products\\\/#listItem\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/products\\\/#listItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/products\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/brand\\\/bertin-nuclear\\\/#listItem\",\"name\":\"Bertin Nuclear\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/brand\\\/bertin-nuclear\\\/#listItem\",\"position\":3,\"name\":\"Bertin Nuclear\",\"item\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/brand\\\/bertin-nuclear\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#listItem\",\"name\":\"LAM-504 Liquid Activity Monitor\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/products\\\/#listItem\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#listItem\",\"position\":4,\"name\":\"LAM-504 Liquid Activity Monitor\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/brand\\\/bertin-nuclear\\\/#listItem\",\"name\":\"Bertin Nuclear\"}}]},{\"@type\":\"ItemPage\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#itempage\",\"url\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/\",\"name\":\"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler\",\"description\":\"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#breadcrumblist\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/etaanalitik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/LAM-504-Liquid-Activity-Monitor.png\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#mainImage\",\"width\":1200,\"height\":1200},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/product\\\/lam-504-liquid-activity-monitor\\\/#mainImage\"},\"datePublished\":\"2026-06-19T13:49:08+00:00\",\"dateModified\":\"2026-09-03T11:45:27+00:00\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#organization\",\"name\":\"ETA Analitik Sistemler\",\"description\":\"Hassas \\u00d6l\\u00e7\\u00fcm, G\\u00fcvenilir \\u00c7\\u00f6z\\u00fcm\",\"url\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/\",\"name\":\"ETA Analitik Sistemler\",\"description\":\"Hassas \\u00d6l\\u00e7\\u00fcm, G\\u00fcvenilir \\u00c7\\u00f6z\\u00fcm\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/etaanalitik.com\\\/en\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler","description":"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.","canonical_url":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/#listItem","position":1,"name":"Home","item":"https:\/\/etaanalitik.com\/en\/","nextItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/products\/#listItem","name":"Products"}},{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/products\/#listItem","position":2,"name":"Products","item":"https:\/\/etaanalitik.com\/en\/products\/","nextItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/#listItem","name":"Bertin Nuclear"},"previousItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/#listItem","position":3,"name":"Bertin Nuclear","item":"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/","nextItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#listItem","name":"LAM-504 Liquid Activity Monitor"},"previousItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/products\/#listItem","name":"Products"}},{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#listItem","position":4,"name":"LAM-504 Liquid Activity Monitor","previousItem":{"@type":"ListItem","@id":"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/#listItem","name":"Bertin Nuclear"}}]},{"@type":"ItemPage","@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#itempage","url":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/","name":"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler","description":"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/etaanalitik.com\/en\/#website"},"breadcrumb":{"@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#breadcrumblist"},"image":{"@type":"ImageObject","url":"https:\/\/etaanalitik.com\/wp-content\/uploads\/2026\/06\/LAM-504-Liquid-Activity-Monitor.png","@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#mainImage","width":1200,"height":1200},"primaryImageOfPage":{"@id":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/#mainImage"},"datePublished":"2026-06-19T13:49:08+00:00","dateModified":"2026-09-03T11:45:27+00:00"},{"@type":"Organization","@id":"https:\/\/etaanalitik.com\/en\/#organization","name":"ETA Analitik Sistemler","description":"Hassas \u00d6l\u00e7\u00fcm, G\u00fcvenilir \u00c7\u00f6z\u00fcm","url":"https:\/\/etaanalitik.com\/en\/"},{"@type":"WebSite","@id":"https:\/\/etaanalitik.com\/en\/#website","url":"https:\/\/etaanalitik.com\/en\/","name":"ETA Analitik Sistemler","description":"Hassas \u00d6l\u00e7\u00fcm, G\u00fcvenilir \u00c7\u00f6z\u00fcm","inLanguage":"en-US","publisher":{"@id":"https:\/\/etaanalitik.com\/en\/#organization"}}]},"og:locale":"en_US","og:site_name":"ETA Analitik Sistemler - Hassas \u00d6l\u00e7\u00fcm, G\u00fcvenilir \u00c7\u00f6z\u00fcm","og:type":"article","og:title":"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler","og:description":"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.","og:url":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/","article:published_time":"2026-06-19T13:49:08+00:00","article:modified_time":"2026-09-03T11:45:27+00:00","twitter:card":"summary_large_image","twitter:title":"LAM-504 Liquid Activity Monitor - ETA Analitik Sistemler","twitter:description":"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids."},"aioseo_meta_data":{"post_id":"10789","title":null,"description":"The LAM-504 Liquid Activity Monitor monitors gamma-emitting radionuclide activity in process liquids.","keywords":null,"keyphrases":{"focus":{"keyphrase":"Aktivite Monit\u00f6r\u00fc","score":75,"analysis":{"keyphraseInTitle":{"score":9,"maxScore":9,"error":0},"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":3},"keyphraseInURL":{"score":5,"maxScore":5,"error":0},"keyphraseInIntroduction":{"score":9,"maxScore":9,"error":0},"keyphraseInSubHeadings":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":[],"keywordDensity":{"score":0,"type":"low","maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"ItemPage","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-08-20 07:57:21","updated":"2026-09-03 13:15:41","seo_analyzer_scan_date":null,"focus_keyword":"Aktivite Monit\u00f6r\u00fc","additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/etaanalitik.com\/en\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/etaanalitik.com\/en\/products\/\" title=\"Products\">Products<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/\" title=\"Bertin Nuclear\">Bertin Nuclear<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tLAM-504 Liquid Activity Monitor\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/etaanalitik.com\/en\/"},{"label":"Products","link":"https:\/\/etaanalitik.com\/en\/products\/"},{"label":"Bertin Nuclear","link":"https:\/\/etaanalitik.com\/en\/brand\/bertin-nuclear\/"},{"label":"LAM-504 Liquid Activity Monitor","link":"https:\/\/etaanalitik.com\/en\/product\/lam-504-liquid-activity-monitor\/"}],"_links":{"self":[{"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/product\/10789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/media\/10791"}],"wp:attachment":[{"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/media?parent=10789"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/product_brand?post=10789"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/product_cat?post=10789"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/etaanalitik.com\/en\/wp-json\/wp\/v2\/product_tag?post=10789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}